全自动造型机故障检测之震击部分 Shaking part of fault detection of automatic molding machine 全自动造型机发生震击无力或不震击有如下几种原因: There are several reasons why the automatic molding machine is unable to shake or does not shake: 1、全自动造型机故障检测遇到空气滤清气堵塞,由于真空泵工作过程产生一些水份,长时间加上管路中一些异物便将空气滤清气中的滤芯堵死,压力表此时看着压力不小,但空气流量不够,造成机器震击无力。 1. In the fault detection of the full-automatic molding machine, the air filter is blocked due to some water produced during the working process of the vacuum pump. The filter element in the air filter is blocked due to a long time plus some foreign matters in the pipeline. The pressure gauge looks at the pressure at this time, but the air flow is not enough, resulting in the weak shock of the machine. 2、由于长时间震动,会出现以下造型机故障:联接震定台与震击活塞的6条M20内六角钉松动,使震台与活塞之间有间隙,工作气流从此处泄漏,造成震击无力,特别是压实后不能震击。 2. Due to long-term vibration, the following molding machine failures will occur: the six M20 hexagon nails connecting the shaking table and the shock piston are loose, so that there is a gap between the shaking table and the piston, and the working air flow leaks from this place, resulting in weak shock, especially after compaction. 3、活塞与泵铁之间不润滑,发生锈纤维 驱鸟设备 保定通风管道 塑料土工格栅 检查井模具 流水槽模具 锻造厂家 华尔街铜牛蚀,也可造成震击无力,解决造型机故障,可打开通往震实台的橡胶管,注入一斤左右的煤油或汽油,然后上好,开机震击,这时震击的声响会有很明显的变化。 3. There is no lubrication between the piston and the pump iron, resulting in corrosion, which may also lead to weak shock. To solve the problem of molding machine, open the rubber pipe to the shaking table, inject about a jin of kerosene or gasoline, and then get on well. Start up the shock. At this time, the sound of the shock will obviously change |